{ "id": 15731, "procurementProjectId": 13776, "noticeNumber": "2019-001095", "reducedTimeLimitsForReceiptOfTenders": false, "corrigendumAdditionalInformation": [], "creatorSystem": "Cloudia Kilpailutus", "type": 100, "legalBasis": "32014L0024", "project": { "id": 0, "title": "X-ray microtomography system", "contractType": 1, "procurementCategory": 1, "jointProcurement": false, "procurementLaw": [], "centralPurchasing": false, "coPurchasers": [], "validationState": 2, "organisation": { "id": "8fa83d2c-7ab7-4148-2d96-08d78deb351a", "information": { "officialName": "It\u00e4-Suomen yliopisto", "nationalRegistrationNumber": "2285733-9", "nutsCodes": [ "FI" ], "postalAddress": { "streetAddress": "Yliopistonranta 1", "postalCode": "70210", "town": "Kuopio", "country": "FI" }, "telephoneNumber": "+358 294458359", "email": "[email protected]", "contactPerson": "Markku Torvinen", "mainUrl": "https:\/\/www.uef.fi\/", "validationState": 2 }, "contractingAuthorityType": 16, "contractingType": 1, "mainActivity": 512, "mainActivityUtilities": 0, "validationState": 0 }, "state": 0, "defenceWorks": 0, "defenceSupplies": 0, "publish": 1, "agricultureWorks": 0, "isPrivate": false, "isConcluded": false }, "lotsInfo": { "divisionLots": false, "lotsSubmittedFor": 0, "lotsSubmittedForQuantity": 0, "lotsMaxAwarded": false, "lotsMaxAwardedQuantity": 0, "lotCombinationPossible": false, "validationState": 2 }, "objectDescriptions": [ { "mainCpvCode": {}, "additionalCpvCodes": [], "nutsCodes": [ "FI" ], "mainsiteplaceWorksDelivery": [ "Kuopio" ], "descrProcurement": [ "The intended X-ray microtomography system is aimed at varied samples. Among other things, the device is utilized in the following areas: material science (plants, wood products, welded seams, metal products), biomedical research (soft tissue, cartilage, bone, teeth), pharmacy, foodstuff, geology, and 3D printing." ], "disagreeAwardCriteriaToBePublished": false, "awardCriteria": { "criterionTypes": 0, "qualityCriteria": [], "costCriteria": [], "priceCriterion": {}, "criterion": [], "criteriaStatedInProcurementDocuments": false }, "estimatedValue": { "type": 0 }, "timeFrame": { "type": 0, "days": 0, "months": 0, "canBeRenewed": false, "renewalDescription": [] }, "candidateNumberRestrictions": { "envisagedNumber": 0, "envisagedMinimumNumber": 0, "envisagedMaximumNumber": 0, "objectiveCriteriaForChoosing": [], "selected": 0 }, "optionsAndVariants": { "variantsWillBeAccepted": false, "partialOffersWillBeAccepted": false, "options": false, "optionType": 0 }, "tendersMustBePresentedAsElectronicCatalogs": false, "euFunds": { "procurementRelatedToEuProgram": false }, "additionalInformation": [], "awardContract": { "contractAwarded": 0, "noAwardedContract": { "failureReason": 0, "originalNoticeSentVia": 0 }, "awardedContract": { "numberOfTenders": { "disagreeTenderInformationToBePublished": false, "total": 0 }, "disagreeContractorInformationToBePublished": false, "contractors": [], "initialEstimatedValueOfContract": {}, "finalTotalValue": { "type": 0 }, "likelyToBeSubcontracted": false, "valueOfSubcontract": {}, "notPublicFields": { "communityOrigin": false, "nonCommunityOrigin": false, "awardedToTendererWithVariant": false, "abnormallyLowTendersExcluded": false } } }, "validationState": 2 } ], "communicationInformation": { "procurementDocumentsAvailable": 0, "additionalInformation": 1, "additionalInformationAddress": { "validationState": 0 }, "otherAddressForProcurementDocuments": { "validationState": 0 }, "sendTendersOption": 0, "addressToSendTenders": { "validationState": 0 }, "electronicCommunicationRequiresSpecialTools": false, "documentsEntirelyInHilma": false, "specsAndAdditionalDocuments": 0, "validationState": 2 }, "contactPerson": { "name": "Markku Torvinen", "email": "[email protected]", "phone": "+358 294458359" }, "procurementObject": { "shortDescription": [ "The suppliers are invited to enter into a dialoque about the requirements of the system, and advise of the different options.\n\nThe intended X-ray microtomography system is aimed at varied samples. Among other things, the device is utilized in the following areas: material science (plants, wood products, welded seams, metal products), biomedical research (soft tissue, cartilage, bone, teeth), pharmacy, foodstuff, geology, and 3D printing." ], "estimatedValue": { "type": 0 }, "mainCpvCode": { "code": "33115000", "name": "Tomography devices", "vocCodes": [] }, "totalValue": { "type": 0 }, "validationState": 2 }, "conditionsInformation": { "economicCriteriaToParticipate": false, "technicalCriteriaToParticipate": false, "restrictedToShelteredWorkshop": false, "restrictedToShelteredProgram": false, "reservedOrganisationServiceMission": false, "executionOfServiceIsReservedForProfession": false, "participationIsReservedForProfession": false, "obligationToIndicateNamesAndProfessionalQualifications": false, "validationState": 0 }, "complementaryInformation": { "isRecurringProcurement": false, "estimatedTimingForFurtherNoticePublish": [], "electronicOrderingUsed": false, "electronicInvoicingUsed": false, "electronicPaymentUsed": false, "additionalInformation": [ "The planned minimum requirements of the system include\n\u2022\tbest resolution one micrometer\n\u2022\ta detector fully covers a sample size of 12x12 cm\n\u2022\ttotal imaging area 20x20 cm achieved by stitching or similarly\n\u2022\tfully motorized movements of the sample stage\n\u2022\tsample size 20x20 cm (diameter x height)\n\u2022\tsample weight carried 5 kg\n\u2022\ta capability to scan a welded seam in a steel pipe with diameter of 100 mm (max) and wall thickness of 4,5 mm (max)\n\u2022\tchangeable X-ray filters\n\u2022\toperating system Windows 10, or Mac OS 10.13, or later\n\u2022\tsoftware for system control, imaging, reconstruction (including tiff -format), image analysis in 2D and 3D, and 3D visualization\n\u2022\tuser training on-site\n\u2022\tdemonstration site for test scans with samples from the buyer\nAdditional or optional features \n\u2022\thelican scanning\n\u2022\tfast imaging in low resolution (60-100 \u00b5m)\n\u2022\tadditional GPU graphics card for fast reconstruction\n\u2022\tsoftware updates\n\u2022\tupgrade possibilities for detector(s) and X-ray tube(s)\n\u2022\tdelivery time 6 months maximum\n\u2022\twarranty 2 years minimum\n\u2022\tmaterial testing stage\n\u2022\ttemperature controlled stage\n\u2022\tautomatic sample changer\nDocuments that descibe the following subjects are demanded\n\u2022\tanalysis parameters calculated\n\u2022\tdata formats\n\u2022\testimated annual costs for consumables and wearing parts\n\u2022\tcontent and costs of service contract\n" ], "validationState": 2 }, "datePublished": "2019-01-17T17:00:11", "state": 2, "tedPublishState": 4, "tedSubmissionId": "20190117-005176", "tedPublishRequestSentDate": "2019-01-16T00:00:00", "tedPublicationInfo": { "ojs_number": "2019\/S 013-025714", "no_doc_ojs": "2019\/S 013-025714", "publication_date": "2019-01-18T10:00:00", "ted_links": {} }, "tedValidationErrors": [], "noticeOjsNumber": "2019\/S 013-025714", "procedureInformation": { "procedureType": 0, "acceleratedProcedure": false, "justificationForAcceleratedProcedure": [], "contestType": 0, "frameworkAgreement": { "includesFrameworkAgreement": false, "includesConclusionOfFrameworkAgreement": false, "frameworkAgreementType": 0, "frameworkEnvisagedType": 0, "includesDynamicPurchasingSystem": false, "dynamicPurchasingSystemInvolvesAdditionalPurchasers": false, "justificationForDurationOverFourYears": [], "dynamicPurchasingSystemWasTerminated": false, "estimatedTotalValue": { "type": 0 }, "duration": { "type": 0, "canBeRenewed": false } }, "reductionRecourseToReduceNumberOfSolutions": false, "reserveRightToAwardWithoutNegotiations": false, "electronicAuctionWillBeUsed": false, "procurementGovernedByGPA": true, "disagreeCriteriaForEvaluationOfProjectsPublish": false, "mainFeaturesAward": [], "validationState": 2 }, "tenderingInformation": { "languages": [], "tendersMustBeValidOption": 0, "tendersMustBeValidForMonths": 0, "estimatedDateOfContractNoticePublication": "2019-02-04T00:00:00", "tenderOpeningConditions": { "place": [], "informationAboutAuthorisedPersons": [] }, "estimatedExecutionTimeFrame": { "type": 3, "canBeRenewed": false }, "validationState": 2 }, "attachments": [], "hasAttachments": false, "changes": [], "isCorrigendum": false, "isMigrated": true, "isCancelled": false, "cancelledReason": [], "isLatest": true, "language": "EN", "proceduresForReview": { "validationState": 0 }, "attachmentInformation": { "description": [], "links": [], "validationState": 2 }, "contractAwardsDefence": [], "annexes": { "d1": { "noTenders": false, "procedureType": 0, "suppliesManufacturedForResearch": false, "providedByOnlyParticularOperator": false, "reasonForNoCompetition": 0, "extremeUrgency": false, "additionalDeliveries": false, "repetitionExisting": false, "designContestAward": false, "commodityMarket": false, "advantageousTerms": false, "advantageousPurchaseReason": 0 } }, "isPrivateSmallValueProcurement": false, "dateCreated": "2019-12-31T14:55:46.0874498", "dateModified": "2020-01-08T22:27:26.797509" }